Resource Library

Find all the Morgan Lens resources you are looking for. 

Resuscitation with Lactated Ringer’s Solution After Hemorrhage: Lack of Cardiac Toxicity

The toxicity of D-lactate has been recognized for almost 30 years. This compound is found in the racemic mixture of lactated Ringer’s solutions routinely used for peritoneal dialysis and the resuscitation of trauma victims. The current study was designed to investigate whether toxicity occurred at the D-lactate concentrations achieved during hemorrhage resuscitation with racemic lactated Ringer’s solution. Conscious unrestrained male Sprague-Dawley rats (n = 24) were monitored for electrocardiographic abnormalities while undergoing hemorrhage and subsequent resuscitation with either L-lactated, D-lactated, or racemic lactated Ringer’s solution. The rats infused with D-lactate showed significant toxicity as evidenced by bradycardia, premature ventricular contractions, and ventricular fibrillation. No such alterations were observed in the animals resuscitated with L-lactate or racemic solutions. Resuscitation with the racemic lactate mixture increased the D-lactate concentrations in the blood, but was not associated with overt changes in cardiac rhythm. The infusion of the different resuscitation fluids produced few significant differences in acid-base status of hemorrhaged rats. These findings indicate that although toxicity may be achieved with a Ringer’s solution containing only D-lactate, resuscitation using the racemic mixture does not achieve D-lactate concentrations high enough to be detrimental to the animal.

Author

Delman K. Malek SK. Bundz S. Abumrad NN. Lang CH. Molina PE, Department of Surgery, State University of New York at Stony Brook

Publication

Shock. 5(4):298-303, 1996 Apr

Morgan Lens Newsletter Sign-Up

* indicates required

”

The Oslo University Eye Department has used the Morgan Lens for 16 years.  We use it in all emergency cases and find that it gives the patients better chances than without this equipment.  In fact, we have reduced the need for hospitalization for more than one night for these patients, and the recovery without scars and permanent loss of visions is far better than without it.  Usually, we don't give our recommendations for products like this, but we have been so happy with the Morgan Lens that we would like to recommend it to all ophthalmologists.  Their patients will benefit from its use.

Physician-Ophthalmologist (Norway)

Why Use The Morgan Lens?

The Morgan Lens is used in 90% of hospital emergency departments in the USA and can be inserted in less than 20 seconds. There simply is no other "hands-free" method of eye irrigation. Nothing else frees medical personnel to treat other injuries or to transport the patient while irrigation is underway. Nothing is more effective at treating ocular chemical, thermal, and actinic burns or removing non-embedded foreign bodies, even when the patient's eyes are closed tightly. Its design makes it simple and straightforward to use so minimal training is required.